For walls, measure their length and height and leave out doors and windows (how to measure walls and openings). For an attic or a floor, use its floor area; the square footage calculator handles odd shapes. Then the drywall calculator covers the walls.

Worked example

400 sq ft of 2 × 4 walls in R-13 batts (106.6 sq ft a bag)

Steps for the worked example
Area to insulate400 sq ft
Insulation in each package106.6 sq ft
Packages (area ÷ package area, rounded up)4 bags

Answer: 4 bags. The area divided by the insulation in each bag, rounded up to whole bags.

Formula and method

bags of batts = ⌈ area × (1 + extra) ÷ square feet per bag ⌉

bags of blown-in = ⌈ area × bags per 1,000 sq ft ÷ 1,000 ⌉

The FTC's R-Value Rule makes every bag of batts state the square feet of insulation inside: the batts' width × length × count. A bag of R-13 batts, 15 × 93 in, holds 106.6 sq ft (Owens Corning), so 400 sq ft of wall takes 4 bags. The studs take up part of the wall, so measuring the whole wall leaves a little to spare. No maker publishes a waste figure, so the extra starts at 0%.

Loose-fill bags carry a chart instead. The stated R-value needs both the bags per 1,000 sq ft and at least the chart's thickness: a 1,000 sq ft attic at R-49 takes 25 bags of AttiCat blown at least 17 in deep.

Batts and rolls

Fiberglass batts by R-value
R-valueThicknessBatt sizePer bagBags for 500 sq ft
R-133.5 in15 in × 93 in11 batts, 106.6 sq ft5
R-133.5 in23 in × 93 in11 batts, 163.39 sq ft4
R-153.5 in15 in × 93 in7 batts, 67.8 sq ft8
R-196.25 in15 in × 93 in8 batts, 77.5 sq ft7
R-196.25 in23 in × 93 in8 batts, 118.8 sq ft5
R-215.5 in15 in × 93 in7 batts, 67.8 sq ft8
R-309.5 in16 in × 48 in11 batts, 58.7 sq ft9
R-309.5 in24 in × 48 in11 batts, 88 sq ft6
R-3812 in16 in × 48 in8 batts, 42.7 sq ft12
R-3812 in24 in × 48 in8 batts, 64 sq ft8

Owens Corning sizes, plus a 23 in R-13 from Johns Manville; other brands pack a different number of batts per bag, so type the square feet from your bag. Batts 15 in wide fit studs 16 in apart; 23 and 24 in batts fit 24 in spacing. An R-19 batt squeezed into a 2 × 6 wall loses some R-value: R-18 (Knauf), R-17 to R-18 (Johns Manville).

Blown-in insulation

Blown-in insulation by R-value
R-valueBags per 1,000 sq ftEach bag coversMinimum thickness
R-135.9169.49 sq ft5 in
R-199111.11 sq ft7 in
R-2210.595.24 sq ft8 in
R-2612.679.37 sq ft9.5 in
R-3014.668.49 sq ft10.75 in
R-381952.63 sq ft13.5 in
R-4422.444.64 sq ft15.5 in
R-492540 sq ft17 in
R-6031.531.75 sq ft20.5 in

Owens Corning AttiCat, 27.5 lb bags (product data sheet, May 2026).

How much R-value you need

Recommended R-values by climate zone
Climate zoneAttic with no insulationAttic with 3 to 4 in alreadyFloor
1R-30R-25R-13
2R-49R-38R-13
3R-49R-38R-19
4A and 4BR-60R-49R-19
4C, 5 and 6R-60R-49R-30
7 and 8R-60R-49R-38

ENERGY STAR's recommended levels for existing wood-framed homes, based on the 2021 International Energy Conservation Code. For walls, it suggests adding R-5 to R-10 insulating sheathing under new siding in zones 4 to 8. Your local code sets the minimum for new work.

Common mistakes

  • Compressing batts. A batt squeezed into a shallower cavity loses R-value.
  • Blowing too few bags at the right depth. Fluffed-up insulation can reach the thickness without the R-value; count the bags too.
  • Comparing bags by price alone. Bags hold different areas, so compare the price per square foot.
  • Covering vents and lights. Keep insulation clear of soffit vents and of recessed lights not rated for contact.

Frequently asked questions

How many square feet does a bag of R-13 cover?

It depends on the bag: 106.6 sq ft for an Owens Corning bag of eleven 15 × 93 in batts. Check the label.

How many bags of blown-in insulation do I need for 1,000 sq ft?

At R-49, 25 bags of AttiCat; the chart above lists other R-values.